Software Release: [TBD]
Section 40
19
00-02-1167
2018-09-18
Figure 19: Service Life Remaining Screens
These two screens provide a list of service reminders and the hours left until the internal alarm will
display the services needed. All the reminders are set to 0.0 Hrs to disable by default and the screens are
hidden by default. The screens can be shown by setting the Show Service Reminders Screens to “Show”
in the service reminders menu.
ISO Icons
The following ISO icons can be displayed on the controller to designate specific parameters and Tier 4
Emission Alerts, as well as Warnings and Shutdowns.
Icon
Description
Displays when High Exhaust System Temperature (HEST) is active and
exhaust temperature is above normal operating condition.
Low diesel exhaust fluid. Displays when the DEF is low.
Displays when engine aftertreatment is in need of regeneration. This is
due to the aftertreatment filter reaching the engine manufacturer's set
soot level for a regeneration to occur.
Displays when the Engine ECU has inhibited a regeneration from
occurring. This should also be shown when inhibiting regeneration
selection is made in the menu.
Displays when an emissions aftertreatment malfunction has occurred.
Contact your local engine manufacturer's service department for direction.
Deutz – Engine Aftertreatment Override Active Status.
Deutz – Wash Bit Ash Load High. Status 1 Solid, Status > 1 Flashing.