![mundoclima H11 Series Service Manual Download Page 38](http://html1.mh-extra.com/html/mundoclima/h11-series/h11-series_service-manual_1856790038.webp)
37
MUPR-09/12/18/24-H11-I
;
MUPR-09/12/18/24-H10X-I
Running
Lamp
Timer Lamp Display
Error Information
1 time
OFF
EH 00/EH
0A
Indoor unit EEPROM parameter error
2 times
OFF
EL 01
Indoor/outdoor unit communication error
3 times
OFF
EH 02
Zero-crossing signal detection error
4 times
OFF
EH 03
The indoor fan speed is operating outside of the
normal range
5 times
OFF
EC 51
Outdoor unit EEPROM parameter error
5 times
OFF
EC 52
Condenser coil temperature sensor T3 is in open
circuit or has short circuited
5 times
OFF
EC 53
Outdoor room temperature sensor T4 is in open
circuit or has short circuited
5 times
OFF
EC 54
Compressor discharge temperature sensor TP is in
open circuit or has short circuited
5 times
OFF
EC 56
Evaporator coil outlet temperature sensor T2B is in
open circuit or has short circuited(for free-match
indoor units)
6 times
OFF
EH 60
Indoor room temperature sensor T1 is in open circuit
or has short circuited
Service manual
MUEX-
H11 series
6 times
OFF
EH 61
Evaporator coil middle temperature sensor T2 is in
open circuit or has short circuited
12 times
OFF
EC 07
The outdoor fan speed is operating outside of the
normal range
9 times
OFF
EH 0b
Indoor PCB/Display board communication error
8 times
OFF
EL 0C
Refrigerant leakage detection
7 times
FLASH
PC 00
IPM malfunction or IGBT over-strong current
protection
2 times
FLASH
PC 01
Over voltage or over low voltage protection
3 times
FLASH
PC 02
Top temperature protection of compressor or High
temperature protection of IPM module or High
pressure protection
5 times
FLASH
PC 04
Inverter compressor drive error
1 time
FLASH
PC 08
Current overload protection
7 times
FLASH
PC 03
Low pressure protection
1 times
ON
--
Indoor units mode conflict
Summary of Contents for H11 Series
Page 1: ...Service manual www mundoclima com CL21400 CL21407 MULTI INVERTER SERIE H11 R32...
Page 11: ...10 MUEX 21 H11 3 MUEX 27 H11 3 Service manual MUEX H11 series...
Page 12: ...11 MUEX 27 H11 3 Service manual MUEX H11 series...
Page 13: ...12 MUEX 36 H11 4 Service manual MUEX H11 series...
Page 14: ...13 MUEX 42 H11 5 Service manual MUEX H11 series...
Page 73: ...www mundoclima com C N POLES 249 P1 08013 BARCELONA SPAIN 34 93 446 27 80 SAT 34 93 652 53 57...