30
9
Indoor unit B capacity demand code
(9K: 1HP,12K: 1.2HP,18K: 1.5HP)
10
Indoor unit C capacity demand code
11
Indoor unit D capacity demand code
12
Indoor unit E capacity demand code
13
Outdoor unit amendatory capacity demand
code
14
The frequency corresponding to the total indoor
units' amendatory capacity demand
15
The frequency after the frequency limit
16
The frequency sending to compressor control
chip
17
Indoor unit A evaporator outlet temperature
(T
2B
A)
If the temperature is lower than -9
ć
, the digital display shows “-9.” If the
temperature is higher than 70
ć
, the digital display shows “70.” If the
indoor unit is not connected, the digital display shows: “――”
18
Indoor unit B evaporator outlet temperature
(T
2B
B)
19
Indoor unit C evaporator outlet temperature
(T
2B
C)
20
Indoor unit D evaporator outlet temperature
(T
2B
D)
21
Indoor unit E evaporator outlet temperature
(T
2B
E)
22
Indoor unit A room temperature (T
1
A)
If the temperature is lower than 0
!
, the digital display shows “0.” If the
temperature is higher than 50
!
, the digital display shows “50.” If the indoor
unit is not connected, the digital display shows: “――”
23
Indoor unit B room temperature (T
1
B)
24
Indoor unit C room temperature (T
1
C)
25
Indoor unit D room temperature (T
1
D)
26
Indoor unit E room temperature (T
1
E)
27
Indoor unit A evaporator temperature (T
2
A)
If the temperature is lower than -9
!
, the digital display shows “-9.” If the
temperature is higher than 70
!
, the digital display shows “70.” If the indoor
unit is not connected, the digital display shows: “――”
28
Indoor unit B evaporator temperature (T
2
B)
29
Indoor unit C evaporator temperature (T
2
C)
30
Indoor unit D evaporator temperature (T
2
D)
31
Indoor unit E evaporator temperature (T
2
E)
32
Condenser pipe temperature (T3)
33
Outdoor ambient temperature (T4)
34
Compressor discharge temperature (TP)
The display value is between 30–129
!
. If the temperature is lower than
30
!
, the digital display shows “30.” If the temperature is higher than 99
!
,
the digital display shows single and double digits. For example, if the digital
display shows “0.5", the compressor discharge temperature is 105
!
.
35
AD value of current
The display value is a hex number.
For example, the digital display tube shows “Cd”, it means AD value is 205.
36
AD value of voltage
37
EXV open angle for A indoor unit
Actual data/4.
If the value is higher than 99, the digital display shows single and double
digits.
For example, if the digital display shows “2.0", the EXV open angle is
120×4=480p.
38
EXV open angle for B indoor unit
39
EXV open angle for C indoor unit
40
EXV open angle for D indoor unit
41
EXV open angle for E indoor unit
42
Frequency limit symbol
Bit7
Frequency limit caused by
IGBT radiator
The display value is a hexidecimal
number. For example, the digital
display show 2A, then Bit5=1,
Bit3=1, and Bit1=1.
This means that a frequency limit
may be caused by T4, T3, or the
current.
Bit6
Frequency limit caused by
PFC
Bit5
Frequency limit caused by
T4.
Bit4
Frequency limit caused by
T2.
Bit3
Frequency limit caused by
T3.
Bit2
Frequency limit caused by
T5.
Bit1
Frequency limit caused by
current
Bit0
Frequency limit caused by
voltage
Service manual
MUEX-
H11 series
Summary of Contents for H11 Series
Page 1: ...Service manual www mundoclima com CL21400 CL21407 MULTI INVERTER SERIE H11 R32...
Page 11: ...10 MUEX 21 H11 3 MUEX 27 H11 3 Service manual MUEX H11 series...
Page 12: ...11 MUEX 27 H11 3 Service manual MUEX H11 series...
Page 13: ...12 MUEX 36 H11 4 Service manual MUEX H11 series...
Page 14: ...13 MUEX 42 H11 5 Service manual MUEX H11 series...
Page 73: ...www mundoclima com C N POLES 249 P1 08013 BARCELONA SPAIN 34 93 446 27 80 SAT 34 93 652 53 57...