GBX24S/GBX24B LIGHT TOWER • OPERATION AND PARTS MANUAL — REV. #0 (05/30/19) — PAGE 19
CONTROL PANEL
Figure 5. GBX24S/GBX24B Control Panel
1
2
3
4
5
6
7
8
9
10
1.
Fuses — Provide circuit protection.
a.
Fuse 1 (5 A) - protects the starter circuit
b.
Fuse 2 (5 A) - protects the circuit of preheating
engine
c.
Fuse 3 (10 A) - protects the ECU
d.
Fuse 4 (20 A) - protects the motor winch case
e.
Fuse 5 (20 A) - protects the engine key switch and
component wiring
f.
Fuse 6 (30 A) - protects the circuit of the engine
heater
2.
Glow Lamp — Lights to indicate engine error.
3.
Ignition Key Switch — Starts the engine.
4.
Actuator Switch — When turned, raises or lowers
the lampstand.
5.
Lamp Breaker — 25A circuit breaker protects lamps
from overload. When there is an overload, breaker trips.
When problem is corrected, press the breaker to reset.
6.
Lamp Switch — When pressed, turns all the lamps
on or off.
7.
Dimming Control Switch — When pressed, changes
the brightness of the lamp from 100% down to 40%.
8.
Dimming Meter — Indicates the percentage of the
lamps' brightness.
9.
Hour Meter — Indicates the number of hours that the
machine has been in use.
10.
Panel Lamp — Lights the panel.
Summary of Contents for GLOBUG GBX24B
Page 58: ...PAGE 58 GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 BLOCK DIAGRAM...
Page 59: ...GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 PAGE 59 AC WIRING DIAGRAM...
Page 60: ...PAGE 60 GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 DC WIRING DIAGRAM...
Page 67: ...GBX24S GBX24B LIGHTTOWER OPERATION AND PARTS MANUAL REV 0 05 30 19 PAGE 67 NOTES...