PAGE 36 —GBX24S/GBX24B LIGHT TOWER • OPERATION AND PARTS MANUAL — REV. #0 (05/30/19)
MAINTENANCE
Figure 29. Electrical Components Maintenance
Table 10. Electrical Components Maintenance
Location
Part
Symptom
Solution
Freq.
Electrical
E1
Lamp Cable
Tangled or damaged?
Untangle or replace.
v
E2
Dimming Board
Does not display properly?
See Troubleshooting.
v
E3
Switches and Meters
Does not work properly?
See Troubleshooting.
v
Connector
E4
Connectors on Control Box
Not properly connected?
Repair as needed.
l
E4
Connectors on Control Box
Burnt Connectors?
Replace.
l
v
- Daily Check
n
- Every 20 Hours
l
- Every 100 hours
s
- Every 500 hours