PAGE 28 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL —REV. #1 (02/25/14)
MAINTENANCE
Figure 24. Location of Maintenance Parts
LAMP
1
MICRO SWITCH
LAMP
1
Table 3. Troubleshooting
SYMPTOM
POSSIBLE PROBLEM
Is plug disconnected?
Is generator power switched off?
Lamp does not light.
Is lamp loose?
Is power connector disconnected or
loose?
Is model of lamp incompatible?
Lamp only lights for a short time.
Is ambient temperature too high -
more than 104° F (40° C)?
Is fan motor not working properly?
Balloon does not inflate.
Is balloon cloth defective?
Is Lamp 1 on but fan is not working?
Only Fan is working.
Is Lamp 1 not turning on?
Shuts down after 30 seconds.
Is Microswitch being pressed?
SOLUTION
Plug in correctly.
Turn on switch.
Screwlamp securely into socket.
Connect disconnected connector.
Use genuine MQlamp.
Move lamp where there is proper
ventilation.
Check and repair fan motor.
Repair or replace balloon cloth.
Check and repair fan motor.
Check Lamps and cable wiring.
Check Microswitch or repair fan motor.