PAGE 20 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL —REV. #1 (02/25/14)
LAMPADAPTERPLATEMOUNTINGINSTALLATION
1. Remove the adapter plate kit hardware from its
container.
2. Before proceeding make sure the light tower mast is
inthestowposition(down) andthecradlelock/release
pin has been inserted and the mast is locked.
3. Attach the lamp adapter plate to the T-Bar as shown
in Figure 7. Align adapter plate so that adapter spacer
notch fits over screw on T-Bar. Pay close attention to
the orientation of the two support brackets.
4. Mount the flat end of both support brackets flush
against the T-Bar with the
low
end of each bracket
facing inwards toward the mast. The
raised
end of
each bracket should be facing outward.
SETUP
5. Next, insert a bolt (4) and flat washer (4) thru the
mountingholesontheadapter plateasshowninFigure
7. Again, pay close attention on which set of holes to
insert the bolts thru.
Bolt number 2
must be oriented
so that it passes between receptacles J1 and J2 on
the T-Bar.
6. Securetheadapter platetotheT-Bar usingthesupplied
flat washer (4), lock washer (4) and nut (4). Make sure
the adapter plate is level (use a bubble level) and both
brackets are straight (vertical), not slanted, before
tightening.
NOTICE
Paycloseattentiontotheorientationof thetwosupport
brackets.Eachbracket hasahighandlowside.Thelow
side of the bracket should be facing inwards towards
the mast.