background image

GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL —REV. #1 (02/25/14) —PAGE 

 

 

DIMENSIONS

 

 

 

 
 
 
 

 

 

 

CLOSED 

OPENED 

 

 

Figure 1. Dimensions

 

 
 
 
 

 

Table 2. Dimensions

 

Reference 

Letter

 

Dimension 

in. (mm)

 

15.7 (400) 

46 (1,170) 

55.1 (1400) 

41.7 (1,060) 

Summary of Contents for GloBug GB4000

Page 1: ...GLOBUG MODEL GB4000 LIGHT TOWER MOUNT TYPE BALLOON LIGHT SERIAL NO G3100044 AND ABOVE Revision 1 02 25 14 THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES OPERATION AND PARTS MANUAL...

Page 2: ...PAGE 2 GB4000 BALLOON LIGHT OPERATION AND PARTS MANUAL REV 1 02 25 14 NOTES...

Page 3: ...PAN Test Rport no Tested to USA SS 17036833 001 Client Reference Satomi Kugimiya CAN CSA C22 2 No 9 0 96 R2011 Certified Product Portable HID luminaire Globug Series License Fee Units Model Designatio...

Page 4: ...16 General Information 17 Components 18 Setup 19 22 LampCableConnections 23 Operation 24 25 Maintenance 26 28 WiringDiagram 29 ExplanationOf CodeInRemarksColumn 30 SuggestedSpareParts 31 TABLE OF CON...

Page 5: ...elcometoorderpartsviaFax Domestic US Customersdial 1 800 6 P ARTS 7 800 672 7877 Faxyour order inandqualifyfor a2 Discount on Standardorders for all orders whichinclude completepartnumbers Note Discou...

Page 6: ...ificallyaddressthelevel ofexposure to the operator and are preceded by one of four words DANGER W ARNING CA UTIONor NOTICE SAFETYSYMBOLS SAFETYSYMBOLS Potential hazards associated with the operation o...

Page 7: ...FORMATION Thisequipment shouldonlybeoperatedbytrainedand qualifiedpersonnel 18yearsof ageandolder Whenevernecessary replacenameplate operationand safetydecalswhentheybecomedifficult read Manufacturer...

Page 8: ...t whileunit isoperating NEVERuse the light tower mast as a crane DONOT liftanythingwiththemast ALWA YSlowerthelighttowerwhennotinuse orifhigh windsor electrical stormsareexpected SAFETY INFORMATION AL...

Page 9: ...e or equipment can result if operating in speed ranges above the maximumallowable NEVERtiptheenginetoextremeanglesduringliftingas it maycauseoil togravitateintothecylinder head making theenginestartdi...

Page 10: ...dandingood operatingcondition ALWA YSshutdownenginebeforetransporting Make sure thehitchand couplingof the towingvehicle are rated equal to or greater than the trailer gross vehicleweight rating SAFET...

Page 11: ...CORD Beforeloadinglight towertoflatbedtruck disconnect all connectorsandtie wrapthecablesagainst theT bar to prevent damagetothecablesandconnectors Remove andstowtheGB4000inasafeplace whereit will not...

Page 12: ...ORMATION Backfeed to a utility system can cause electrocution and orpropertydamage NEVERconnectthegenerator toabuilding selectricalsystemwithoutatransferswitch or other approved device All installatio...

Page 13: ...andling thebatterytoavoideyeirritation Thebattery containsacidsthatcancauseinjurytothe eyesandskin Usewell insulatedgloveswhenpickingupthebattery ALWA YSkeepthebatterycharged If thebatteryisnot charge...

Page 14: ...WMetal Halide X4 Number of Bulbs 4 Current 37 2A 9 3Ax4 Voltage 120V Lumens 428 000 10 700x4 lm Fan Current 1 2A Voltage 24VDC Dimensions Storage 15 7x15 7x45 6in 400x400x1160mm Working 55 1x55 1x47 2...

Page 15: ...LLOONLIGHT OPERA TIONANDPARTSMANUAL REV 1 02 25 14 PA GE DIMENSIONS CLOSED OPENED Figure 1 Dimensions Table2 Dimensions Reference Letter Dimension in mm A 15 7 400 B 46 1 170 C 55 1 1400 D 41 7 1 060...

Page 16: ...LIGHT OPERA TIONANDPARTSMANUAL REV 1 02 25 14 FOOTCANDLE PLOT 1 grid 40 ft Illuminance Footcandle 30 20 10 5 2 1 0 5 0 25 0 1 Diameter Feet 46 60 78 98 149 205 259 314 426 Figure 2 Footcandle Plot 30...

Page 17: ...sites securitysupport and special events Theballoonlight assemblyissupportedbyfour1000 watt metal halidelamps self inflatingdurablepolyesterballoon bag protective lamp guard quick disconnect communal...

Page 18: ...flationcircuit 4 Adapter Plate Attaches to the T Bar and mast interface of the light tower to allowthe GB4000 to be installed NOTICE Thisadapter plate item4 fitsmost conventional light tower masts 5 J...

Page 19: ...resultinequipment damage seriousinjuryordeath 2 If thelight towerisinthedeployedposition placethe tower mast intothecradlesupport stowedposition SeeFigure4 Makesurecradlelock releasepinhas beeninserte...

Page 20: ...st the T Bar with the low end of each bracket facing inwards toward the mast The raised end of eachbracket shouldbefacingoutward SETUP 5 Next insert a bolt 4 and flat washer 4 thru the mountingholeson...

Page 21: ...FLUSH W T BAR BOTTOM SUPPORT BRACKET 2 BOLT T BAR T BAR LAMP ADAPTER PLATE BOLT 4 1 BACK SIDE UNDERNEATH BOLT 2 2 3 LAMP ADAPTER PLATE NOTES 4 SUPPORT BRACKET J1 J2 1 It is important for the adapter S...

Page 22: ...ting 1 PlacetheGB4000lampfi tureontothelampadapter platepoleasshowninFigure9 2 Insertlockingpinintoholeopeningonpole theninsert cotterpintolockpininplace BALLOONPOWERCABLE 1 Connect theballoonpowercab...

Page 23: ...xisting rectangular lamps When the GB4000 lamp assembly is employed these receptacles are used to connect the GB4000 Refer toFigure10 GB4000 T BAR JUNCTION BOX NOTE CABLE FROM LAMP 1 MUST BE CONNECTED...

Page 24: ...Removing Protective Cover 2 Next fold the protective cover into itself and zip See Figure11 INFLA TINGBALLOONANDTURNINGONLAMPS LT12ONL Y 1 OnL T12serieslighttowers reconnectnegativebattery cable blac...

Page 25: ...ble 2 Slightly raise the light tower mast to allowclearance fortheballoontoinflate 3 Start the light tower engine as referenced in the MLT operationmanual 4 Once the engine has started place the main...

Page 26: ...lampguards SeeFigure16 Figure 18 Removing Lamp 5 Install new lamp into socket and turn lamp in a clockwisedirectionuntiltight SeeFigure19 Figure 19 Installing New Lamp LOCK HOOK Figure 16 Removing Lam...

Page 27: ...ALLOON 1 Unzipthetopandbottomoftheballoon SeeFigure20 INSTALL NEW BALLOON BALLOON UNZIP TOP AND BOTTOM ZIPPERS Figure 22 Replacing Balloon 4 Zip up the top and bottomof the newballoon See Figure23 Fig...

Page 28: ...for ashort time Isambient temperaturetoohigh morethan104 F 40 C Isfanmotor not workingproperly Balloondoesnotinflate Isballoonclothdefective IsLamp1onbut fanisnot working OnlyFanisworking IsLamp1not t...

Page 29: ...F F POLE R M M DC FAN MOTOR F F F F CABLE POLE W M M RELAY BLUE M M M M M M M F F F F F F F F F F F CABLE BALLOON F M F M DC CONVERTER GREEN CABLE PANEL BALLOON MICROSWITCH M M M M M M F F M M M M BOX...

Page 30: ...een assigned a formal part number at thetimeof publication Ablankentrygenerallyindicatesthat theitemisnot sold separatelyoris notsoldbyMultiquip Otherentrieswill beclarifiedinthe Remarks Column QTY Co...

Page 31: ...GE GB4000BALLOONLIGHT 1to3units Qty P N Description 2 E000127300 LAMP 2 A100097802 BALLOONCOVERCP 3 A400038301 FILTER SUGGESTED SPARE PARTS NOTICE Part numbersonthisSuggestedSparePartslist may supers...

Page 32: ...es et r duire la dur e de vie utile de la lampe INFOR MAT ION S S UR LE BALLON NE JAMAIS laisser le ballon toucher la surface de lampe lorsque celle ci est chaude fromdust dirtandadverseweather condit...

Page 33: ...1 2 A400336800 DECAL D ANGER ELECTRICALSHOCKHAZARD FRENCH 1 3 A400252600 DECAL WARNING BURNHAZARD ENGLISH 1 3 A400336900 DECAL WARNING BURNHAZARD FRENCH 1 4 DECAL SERIALPLA TE 1 C O N T A C TM Q P AR...

Page 34: ...4 5 6 10 2 12 11 12 17 13 14 15 36 23 16 17 19 18 17 20 25 20 21 23 22 16 27 1 24 31 26 28 29 30 1 32 33 34 33 39 37 34 22 21 62 63 38 23 16 38 37 25 35 40 18 36 41 42 15 14 43 62 63 26 64 27 36 17 19...

Page 35: ...ASHER M4x15 8 19 A400327202 HOLDER GUARD 4 20 0033206000 SELFLOCKNUT M6 8 21 A300285400 SOCKETASSY 4 22 E000038200 CAP RUBBER 4 23 A400321501 STOPPER 14 24 A300278801 LAMPHOLDER2 1 25 A200097703 PLA T...

Page 36: ...8 9 4 5 6 10 2 12 11 12 17 13 14 15 36 23 16 17 19 18 17 20 25 20 21 23 22 16 27 1 24 31 26 28 29 30 1 32 33 34 33 39 37 34 22 21 62 63 38 23 16 38 37 25 35 40 18 36 41 42 15 14 43 62 63 26 64 27 36...

Page 37: ...1 50 0013112030 BOLT M12x30 1 51 A200100502 FLANGE 1 52 E000099000 PIN 1 53 1800001100 SHEET BOTTOM 1 54 A300283300 PLA TE GUARD 1 55 A200076103 PLA TE BOTTOM 1 56 A400038301 FILTER 200 1 57 E0001193...

Page 38: ...PAGE 38 GB4000 BALLOON LIGHT OPERATION AND PARTS MANUAL REV 1 02 25 14 BRACKET AND J BOX ASSY...

Page 39: ...304012 7 0033104000 NUT M4 4 8 A100088602 ADAPTERCP 1 9 E000122700 WASHER 4 10 A400288001 RET AINER 2 11 A300215302 CABLE LAMP 3CP 4 12 A300283800 CABLE LAMP 2CP 1 13 0013112130 BOLTM12x130 4 14 00135...

Page 40: ...perproducts h Itemspurchasedinkits 7 Thesenderwillbenotifiedofanymaterial receivedthatisnotacceptable 8 Such material will be held for five working days fromnotification pending instructions If a repl...

Page 41: ...GB4000 BALLOON LIGHT OPERATION AND PARTS MANUAL REV 1 02 25 14 PAGE 41 NOTES...

Page 42: ...field CheshireSK164UJ Contact sales multiquip co uk T el 0161 339 2223 Fax 01613393226 COPYRIGHT2014 MULTIQUIPINC MultiquipInc theMQlogoareregisteredtrademarksof MultiquipInc andmaynotbeused reproduce...

Reviews: