Settings
The Settings function modifies the kerf width and lead-in presence and status.
1. Press
Menu
to access the menu system.
2. Press
X-axis Jog Arrows
until Params_2D is highlighted in blue.
3. Press
Enter
to access the Params_2D sub-menu.
4. Press
X-axis Jog Arrows
until Settings is highlighted in blue.
5. Press
Enter
to change the kerf width and lead in status.
a. Kerf Width
i. Press
Enter
over Kerf Width.
ii. Enter the corrected value using the number keypad. Negative numbers should be used for an inside cut.
iii. Press
Enter
to confirm the value and return to the Settings sub-menu.
b. Lead In
i. Press
Enter
over Lead In.
ii. Press
Enter
to toggle between YES and NO.
c. Lead In Length
i. Press
Enter
over Lead In Length.
ii. Enter the Lead In Length value using the number keypad.
iii. Press
Enter
to confirm the value and return to Settings sub-menu.