MI
10
Innovation. Quality. Performance. Best in Industry. Worldwide.
Voltage
The Voltage function adjusts the automatic torch height voltage to maintain a constant distance from the tip of the
torch to the top of the material and will vary based on material type, thickness, feedrate, and changes in torch
consumables.
Operators must refer to the plasma unit manual for the specific voltage setting
.
An increase in voltage is proportional to an increase in height. If the voltage is set to 0, then the machine will
attempt to automatically calculate the voltage. The Params_2D sub-menu will show whether the system was set to
Auto or to what level the voltage was adjusted.
Voltage is only available if Z Tracking is enabled
.
1. Press
Menu
to access the menu system.
2. Press
X-axis Jog Arrows
until Params_2D is highlighted in blue.
3. Press
Enter
to access the Params_2D sub-menu.
4. Press
X-axis Jog Arrows
until Voltage is highlighted in blue.
5. Press
Enter
to adjust the voltage settings.
6. Enter the desired voltage value from the number keypad (e.g., 124).
a. If the operator chooses to enter a specific value for voltage, then he or she should toggle to NO for the
Sample ATHC.
b. If the operator chooses to allow the machine to automatically configure the voltage, then he or she should
toggle to Yes for Sample ATHC.
7. Press
Enter
to accept the value and return to the Params_2D sub-menu.
If the operator toggles the Sample ATHC to Yes, then the Params_2D sub-menu will show Auto for Voltage.
Routers * Lasers * Plasma * Water Jets * Knife Cutters