MI
40
Innovation. Quality. Performance. Best in Industry. Worldwide.
Start Digitize
The Start Digitize function configures the system to begin 2D digitizing. Operators
should not use
this menu
option until all other Digitize options have been set.
1. Place the object to be scanned on a contrasting sacrifice material. A white object on a dark background will
have a better contrast than a wooden object on MDF.
2. Turn on the table vacuum to hold the part flat to the sacrifice material. Warped material can introduce errors in
the scanning process.
3. Lower the LED probe to usually about 3/8” – 1/2” above the material. The numbers on the counter will decline
(e.g., 70
→
134 and then 134
→
16) at the contrast edge.
4. Raise the probe until the counter shows the higher number (e.g., 134) and press the Set button. This will
save the highest point of contrast in the system.
Set Button
5. Press
Menu
to access the menu system.
Routers * Lasers * Plasma * Water Jets * Knife Cutters