362 – AL Power Stage high
ZKP-Number: 1.8004.497
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty: start
ITS).Check additional messages
if ITS indicates diagnosis
"Electronics OK" (e.g. cabling
faulty).
1. Check solenoid valve cabling.
2. Replace Engine Control Unit.
363 – AL Stop Power Stage
ZKP-Number: 1.8004.560
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty: start
ITS).
1. Check cabling.
2. Attempt to restart engine.
365 – AL Stop MV-Wiring Ground
ZKP-Number: 1.8004.561
Cause
Corrective action
Injector cabling fault. If bit
"1.1020.021" (power stage
failure: Stop engine) is set,
engine is additionally stopped in
this case. 1. Short circuit of
in connection of one or
more injectors to ground 2. Short
circuit of injector – connection of
one or more injectors to ground.
1. Check cabling.
2. Attempt to restart engine.
371 – AL Wiring TO 1
ZKP-Number: 1.8004.634
Cause
Corrective action
Short circuit or wire break on
transistor output 1 (TO 1).
1. Check charger valve/cabling, repair as necessary.
2. Replace Engine Control Unit.
372 – AL Wiring TO 2
ZKP-Number: 1.8004.635
Cause
Corrective action
Short circuit or wire break on
transistor output 2 (TO 2).
1. Check recirculation valve/cabling, repair as necessary.
2. Replace ECU.
M015710/04E 2012-09 | Troubleshooting | 111
TIM-ID: 0000008506 - 002