3.6 12V 4000 Gx3 engine data: Standby operation 3D, optimized
fuel consumption
Explanation
Abbrevia‐
tion
Meaning
DL
Ref. value: Continuous power
BL
Ref. value: Fuel stop power
A
Design value
G
Guaranteed value
R
Guideline value
L
Limit value, up to which the engine can be operated, without change (e.g. of power set‐
tings).
N
Not yet defined value
-
Not applicable
X
Applicable
Reference conditions
Engine model
12V
4000G23
12V
4000G43
12V
4000G63
12V
4000G83
Application group
3D
3D
3D
3D
Intake air temperature
°C
25
25
25
25
Charge-air coolant temperature
°C
55
55
55
55
Raw-water inlet temperature
°C
-
-
-
-
Barometric pressure
mbar
1000
1000
1000
1000
Site altitude above sea level
m
100
100
100
100
Power-related data (power ratings are net brake power to ISO 3046)
Number of cylinders
12
12
12
12
Rated engine speed
A rpm
1500
1800
1500
1800
Fuel stop power ISO 3046
A kW
1575
1736
1750
1910
General conditions (for maximum power)
Number of cylinders
12
12
12
12
Intake depression (new filter)
A mbar
15
15
15
15
Intake depression, max.
L mbar
50
50
50
50
Exhaust overpressure
A mbar
30
30
30
30
Exhaust overpressure, max.
L mbar
85
85
85
85
44 | Technical Data | M015710/04E 2012-09
TIM-ID: 0000002873 - 002