3 Technical Data
3.1 Engine data 8V4000M24S, Marine EPA Tier 3, IMO Tier II
Explanation
Index (I)
Meaning
DL
Ref. value: Continuous power
BL
Ref. value: Fuel stop power
A
Design value
G
Guaranteed value
R
Guideline value
L
Limit value up to which the engine can be operated, without change (e.g. of power setting)
N
Not yet defined value
-
Not applicable
X
Applicable
Reference conditions
(I)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Application group
3A
3A
3A
3A
Intake air temperature
°C
25
45
25
45
Charge-air coolant temperature
°C
-
-
-
-
Raw water inlet temperature
°C
25
32
25
32
Barometric pressure
mbar
1000
1000
1000
1000
Site altitude above sea level
m
100
100
100
100
Power-related data (power ratings are net brake power as per ISO 3046)
(I)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Rated engine speed
A
rpm
1800
1800
1800
1800
Fuel stop power ISO 3046
A
kW
985
985
985
985
General conditions (for maximum power)
(I) Unit
Engine-mounted heat
exchanger
Remote heat ex-
changer
Intake depression (new filter)
A
mbar
15
15
15
15
Intake depression, max.
L
mbar
30
30
30
30
Exhaust gas overpressure
A
mbar
30
30
30
30
Exhaust gas overpressure, max.
L
mbar
85
85
85
85
Fuel temperature at engine inlet connec-
tion
R
°C
25
25
25
25
Fuel temperature at engine supply con-
nection, max.
L
°C
55
55
55
55
MS150109/01E 2015-11
| Technical Data | 57
TIM-ID: 0000045044 - 001