588 – SD P-Oil Refill Pump
ZKP-Number: 1.0159.910
Signal error, refill pump oil pressure sensor
Yellow alarm; warning
Cause
Corrective action
Pressure sensor faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 254).
2. Contact Service.
593 – AL T-Lube Oil in Oil Pan too Low
ZKP-Number: 2.1090.929
Lube oil temperature in oil pan is too low.
Cause
Corrective action
Preheating time is insufficient.
1. Extend preheating period.
2. Contact Service.
596 – AL Test Parameters
ZKP-Number: 1.8004.645
Yellow alarm; warning
Cause
Corrective action
The parameter record is used for
trials. The alarm remains set until
a series parameter set is loaded.
u
Contact Service.
600 – SD T-Exhaust A+B
ZKP-Number: 1.8004.646
Signal error, exhaust temperature sensor A- and B-side
Yellow alarm; warning
Cause
Corrective action
Exhaust temperature sensor on A-
and B-side faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 254).
2. Contact Service.
601 – SD ETC1+ETC2
ZKP-Number: 1.3011.227
Signal error, ETC speed sensor 1 and 2
Yellow alarm; warning
Cause
Corrective action
ETC speed sensors 1 and 2 faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 254).
2. Contact Service.
158 | Troubleshooting | MS150109/01E 2015-11
TIM-ID: 0000045495 - 002