394 – LO P-Lube Oil Red
ZKP-Number: 2.0112.921
Limit value 1
Cause
Corrective action
Redundant lube oil pressure
reading too low.
1. Check wiring and sensor.
2. Contact Service.
395 – SS P-Lube Oil Red
ZKP-Number: 2.0112.922
Limit value 2
Cause
Corrective action
Redundant lube oil pressure
reading too low.
1. Check wiring and sensor.
2. Contact Service.
396 – TD T-Coolant Sensor Deviation
ZKP-Number: 1.0480.193
Cause
Corrective action
Maximum coolant temperature
deviation.
1. Check wiring and sensor.
2. Contact Service.
397 – TD P-Oil Sensor Deviation
ZKP-Number: 1.0480.293
Cause
Corrective action
Maximum lube oil pressure
deviation.
1. Check wiring and sensor.
2. Contact Service.
400 – AL Open Load Digital Input 1
ZKP-Number: 2.8006.625
Line disruption on digital input 1
Yellow alarm; warning
Cause
Corrective action
Wiring faulty.
No resistance over switch.
1. Check wiring (→ Page 254).
2. Check target device input.
3. Contact Service.
MS150109/01E 2015-11
| Troubleshooting | 139