456 – AL L2 Aux1 Plant
ZKP-Number: 2.8006.651
Limit value 2
Cause
Corrective action
Input signal of Aux 1 (plant side)
has exceeded/not attained limit
value 2, depending on
configuration.
u
Determine cause of limit value violation and rectify fault.
460 – HI T-Exhaust EMU
ZKP-Number: 2.8006.652
Limit value 1
Cause
Corrective action
EMU exhaust gas temperature
value too high.
1. Check wiring.
2. Contact Service.
461 – LO T-Exhaust EMU
ZKP-Number: 2.8006.653
Limit value 1
Cause
Corrective action
EMU exhaust gas temperature
value too low.
1. Check wiring.
2. Contact Service.
462 – HI T-Coolant EMU
ZKP-Number: 2.8006.654
Limit value 1
Cause
Corrective action
EMU coolant temperature value
too high / low.
u
Check configuration with DiaSys.
464 – SD P-AUX 1
ZKP-Number: 1.8004.589
Cause
Corrective action
Analog input signal for Aux 1
pressure faulty; Short circuit or
wire break.
u
Check pressure transmitter and wiring, replace as necessary.
Fault is rectified when engine is restarted.