4.20 Product data 20V4000G14S, 20V4000G24S, 20V4000G44S,
application group 3G
Key
DL Reference value: Continuous power. continuously attainable power at standard conditions
BL Reference value: Fuel stop power. Maximum engine power. Not continuously attainable in some appli-
cations (margin for load fluctuations).
A Design value. Value required to design an external system (plant).
R Guideline value. Typical average value for information, only partially suitable for design purposes.
L Limit value. Value which must not be violated (lower limit value, min. value / upper limit value, max.
value), not suitable for design purposes
N Not yet defined value. Value has not yet been defined or will not be defined
- Not applicable. Module is not applicable to the given product type.
X Applicable. Module is applicable to the given product type.
> Actual value must be greater than the specified value.
< Actual value must be less than the specified value.
* Not sufficiently validated value (+/- 10% tolerance).
** Not sufficiently validated value (+/- 5% tolerance).
ID
Product type
Application
Speed
Nominal pow-
er
1
20V4000G14S Power generation
3G prime power, time-
limited, ICXN
1800 rpm
60 Hz
2490 kW
3339 bhp
Ref. 25 °C/55 °C
Optimized fuel con-
sumption
2
20V4000G14S Power generation
3G prime power, time-
limited, ICXN
1800 rpm
60 Hz
2490 kW
3339 bhp
Ref. 25 °C/45 °C
EPA Nonroad T2 Comp
(40CFR89)
3
20V4000G24S Power generation
3G prime power, time-
limited, ICXN
1800 rpm
60 Hz
2740 kW
3674 bhp
Ref. 25 °C/55 °C
Optimized fuel con-
sumption
4
20V4000G24S Power generation
3G prime power, time-
limited, ICXN
1800 rpm
60 Hz
2740 kW
3674 bhp
Ref. 25 °C/45 °C
EPA Nonroad T2 Comp
(40CFR89)
5
20V4000G44S Power generation
3G prime power, time-
limited, ICXN
1800 rpm
60 Hz
3010 kW
4036 bhp
Ref. 25 °C/55 °C
Optimized fuel con-
sumption
6
20V4000G44S Power generation
3G prime power, time-
limited, ICXN
1800 rpm
60 Hz
3010 kW
4036 bhp
Ref. 25 °C/45 °C
EPA Nonroad T2 Comp
(40CFR89)
Reference conditions
ID
1
2
3
4
5
6
Intake air temperature
°C
25
25
25
25
25
25
Charge-air coolant tem-
perature
°C
55
45
55
45
55
45
Barometric pressure
mbar
1000
1000
1000
1000
1000
1000
Site altitude above sea
level
m
100
100
100
100
100
100
MS15039/01E 2018-11
| Technical Data | 127