88
Troubleshooting
Fault
code No.
Designation
Meaning
Task
Related
parameter No.
401
AL Open Load Digital
Input 2
Alarm configuration; Line
disruption on digital input 2;
Cabling faulty or no resistance
over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.626
402
AL Open Load Digital
Input 3
Alarm configuration; Line
disruption on digital input 3;
Cabling faulty or no resistance
over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.627
403
AL Open Load Digital
Input 4
Alarm configuration; Line
disruption on digital input 4;
Cabling faulty or no resistance
over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.628
404
AL Open Load Digital
Input 5
Alarm configuration; Line
disruption on digital input 5;
Cabling faulty or no resistance
over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.629
405
AL Open Load Digital
Input 6
Alarm configuration; Line
disruption on digital input 6;
Cabling faulty or no resistance
over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.630
406
AL Open Load Digital
Input 7
Alarm configuration; Line
disruption on digital input 7;
Cabling faulty or no resistance
over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.631
407
AL Open Load Digital
Input 8
Alarm configuration; Line
disruption on digital input 8;
Cabling faulty or no resistance
over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.632
408
AL Open Load Emerg.
Stop Input ESI
Alarm configuration; Line
disruption on the input for
emergency stop; Cabling faulty
or no resistance over switch.
1. Check cabling
2. Check input of
target device.
3. Contact
Service.
2.8006.633
410
LO U-PDU
Alarm configuration limit
value 1; Preliminary warning:
Injector voltage too low.
1. Check cabling.
2. Check power
supply.
3. Contact
Service.
2.0141.921
411
LOLO U-PDU
Alarm configuration limit value
2; Main warning: Injector
voltage too low.
1. Check cabling
2. Check power
supply.
3. Contact
Service.
2.0141.922
M015715/00E 06-08
© MTU
Summary of Contents for 20 V 4000 G23
Page 9: ...04 Table of Contents M015715 00E 06 08 MTU...
Page 19: ...14 Safety M015715 00E 06 08 MTU...
Page 61: ...56 Operation M015715 00E 06 08 MTU...
Page 73: ...68 Maintenance M015715 00E 06 08 MTU...
Page 159: ...154 Task Description M015715 00E 06 08 MTU...
Page 165: ...160 Special Tools M015715 00E 06 08 MTU...
Page 171: ...166 Annex M015715 00E 06 08 MTU...
Page 175: ......
Page 176: ...Demo version http www verypdf com...
Page 177: ...Demo version http www verypdf com...
Page 178: ...Demo version http www verypdf com...