3.3
Starting the engine in manual mode
Preconditions
• Generator is not connected to network.
• External start interlock is not activated.
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury — danger to life!
• Before barring or starting the engine, ensure that nobody is in the danger zone.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
• Wear ear protectors.
Preparation
Item
Task
Operating mode selector switch (if
provided)
Change to manual mode.
Preheating pump (if provided)
Switch ON.
Starting the engine
Item
Task
Switching cabinet, control panel etc.
(depending on manufacturer)
If coolant temperature is
• > 40 °C (with preheating pump), or
• > 10 °C (60 Hz generator, without preheating pump), or
• > 5 °C (50 Hz generator, without preheating pump):
Press start button.
• Automatic starting procedure is performed;
• Tachometer indicates increasing crankshaft speed;
• After the starting procedure is completed, engine is running at
rated speed.
Connecting the generator to network, running the engine to reach operating temperature
Item
Task
Switching cabinet, control panel etc.
(depending on manufacturer)
Close the generator circuit breaker.
Engine
Run engine at 10 to 15 % of rated power to reach operating temperature.
Apply full load only after engine has reached operating temperature
(coolant temperature approx. 75 °C).
M015715/00E 06-08
© MTU
Summary of Contents for 20 V 4000 G23
Page 9: ...04 Table of Contents M015715 00E 06 08 MTU...
Page 19: ...14 Safety M015715 00E 06 08 MTU...
Page 61: ...56 Operation M015715 00E 06 08 MTU...
Page 73: ...68 Maintenance M015715 00E 06 08 MTU...
Page 159: ...154 Task Description M015715 00E 06 08 MTU...
Page 165: ...160 Special Tools M015715 00E 06 08 MTU...
Page 171: ...166 Annex M015715 00E 06 08 MTU...
Page 175: ......
Page 176: ...Demo version http www verypdf com...
Page 177: ...Demo version http www verypdf com...
Page 178: ...Demo version http www verypdf com...