RAW WATER CIRCUIT (open circuit)
Number of cylinders
12
Raw water pump: Inlet pressure, min.
L
bar
-0.2
Raw water pump: Inlet pressure , max.
L
bar
0.5
Pressure loss in external raw water system, max.
L
bar
0.7
LUBE OIL SYSTEM
Number of cylinders
12
Lube oil operating temperature before engine, from
R
°C
72*
Lube oil operating temperature before engine, to
R
°C
80*
Lube oil operating pressure before engine, from
R
bar
6
Lube oil operating pressure before engine, to
R
bar
8
Lube oil operating pressure, low idle (meas. point: before engine)
R
bar
2.0
FUEL SYSTEM
Number of cylinders
12
Fuel pressure at engine supply connection, min. (when engine is starting)
L
bar
-0.1
Fuel pressure at engine supply connection, min. (when engine is running)
L
bar
-0.3
Fuel pressure at engine supply connection, max. (when engine is starting)
L
bar
1.5
Fuel supply flow, max.
R
liter/min
30
GENERAL OPERATING DATA
Number of cylinders
12
Firing speed, from
R
rpm
80
Firing speed, to
R
rpm
120
STARTING (electric)
Number of cylinders
12
Starter, rated voltage (standard design)
R
V=
24
STARTING (with compressed air/hydraulic starter)
Number of cylinders
12
Starting-air pressure before starter motor, min.
R
bar
8
Starting-air pressure before starter motor, max.
R
bar
10
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders
12
Longitudinal inclination, continuous max., driving end down (option: max. oper-
ating inclinations)
L
Degrees
15
Longitudinal inclination temporary max. drive side down (design: max. operat-
ing inclinations)
L
Degrees
22.5
MS150047/05E 2018-08
| Technical Data | 65
TIM-ID: 0000010911 - 002
Summary of Contents for 12V4000M93 series
Page 1: ...Operating Instructions Diesel engine 12V4000M93x 16V4000M93x MS150047 05E...
Page 3: ......
Page 4: ......