Emergency measures prior to engine start for continued operation with leak-
ing intercooler
1.
Remove injectors (→ Page 173).
2.
Bar engine manually (→ Page 156).
3.
Bar engine with starting system to blow out combustion chambers (→ Page 156).
4.
Install injectors (→ Page 173).
MS150047/05E 2018-08