7.1.3 Adhesive tape for SOLAS shielding – Application
Preconditions
☑
Engine shut down and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Adhesive tape
X00026424
1
Note:
Use the cable clamp to make a drainage channel. This allows fluid to flow out without pressure in case of
leakage.
Applying adhesive tape – gener-
al information
1.
Place cable clamp (3) on union.
2.
Affix adhesive tape (1) such that lettering (2)
faces out.
3.
Wrap adhesive tape without tensioning.
4.
Pull out cable clamp (3) after affixing adhe-
sive tape.
Taping sealing cone unions, installation locations
1.
2.
Wrap three layers of adhesive tape from the
middle of the sealing cone union to area (A)
for at least 30 mm, ensuring that the adhe-
sive tape overlaps at least half its own width.
3.
Wrap three layers of adhesive tape from the
middle of the sealing cone union to area (B)
for at least 30 mm, ensuring that the adhe-
sive tape overlaps at least half its own width.
154 | SOLAS | MS150047/05E 2018-08