Plugs and sensors, plug-in pipe unions
Seal plugs and sensors (a)
Screw seal plugs (4) are either sealed with copper sealing rings (1) as per DIN or O-rings (ISO).
In case of a loose union or a faulty sealing ring (1), the liquid first has to pass the thread.
The pressure is so greatly reduced by this and the faulty sealing ring (1) that any leakage is not under pres-
sure.
Plug-in pipe connection (b)
The sleeve (3) covers the union to prevent lateral spray.
Only seepage along the pipeline is possible whereby the pressure is greatly reduced by a faulty O-ring (2).
The union is confirmed as being SOLAS-compliant by DNV and GL.
MS150047/05E 2018-08
| General Information | 41
TIM-ID: 0000010056 - 006
Summary of Contents for 12V4000M93 series
Page 1: ...Operating Instructions Diesel engine 12V4000M93x 16V4000M93x MS150047 05E...
Page 3: ......
Page 4: ......