7.24 Emergency Instrumentation (Local Operating Panel)
7.24.1 LOP and connectors – Cleaning
Preconditions
☑
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Solvent (isopropyl alcohol)
X00058037
1
Cleaning LOP
1.
Wipe LCD screen with dry cloth, without applying excessive pressure.
2.
Remove dirt from pushbuttons using solvent.
3.
Remove coarse dirt on housing surface using solvent.
Cleaning connectors on LOP
1.
Remove dirt from connector and socket surfaces using solvent.
2.
Check legibility of cable labels. Clean or replace illegible labels.
246 | Emergency Instrumentation (Local Operating Panel) | MS150047/05E 2018-08
TIM-ID: 0000008867 - 007