1.4520.584 – MIC5 IPE Primary Open Cylinder 15
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 15 in ignition sequence.
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
1.4520.585 – MIC5 IPE Primary Open Cylinder 16
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 16 in ignition sequence.
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
1.4520.586 – MIC5 IPE Primary Open Cylinder 17
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 17 in ignition sequence.
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
1.4520.587 – MIC5 IPE Primary Open Cylinder 18
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 18 in ignition sequence.
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
1.4520.588 – MIC5 IPE Primary Open Cylinder 19
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 19 in ignition sequence.
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
1.4520.589 – MIC5 IPE Primary Open Cylinder 20
Red alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in primary circuit of
cylinder 20 in ignition sequence.
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
1.4520.590 – MIC5 IPE Prim Short Circuit Cyl 1
Red alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in primary circuit of
cylinder 1 in ignition sequence.
1. Check cabling to ignition coil (→ Page 202).
2. Check ignition coil.
96 | Troubleshooting | MS150104/03E 2017-09