
1.4540.033 – Battery Volt High Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Supply voltage has reached
maximum limit value.
1. Check supply voltage.
2. Check cabling (→ Page 202).
1.4540.034 – FGT High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Gas temperature before TecJet is
above the preset limit value.
1. Check TecJet settings.
2. Check gas temperature.
1.4540.035 – Delta P High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Pressure difference through
TecJet above the preset limit
value.
1. Check TecJet settings.
2. Check gas pressure.
1.4540.036 – FGP High Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Gas pressure before TecJet is
above the preset limit value.
1. Check TecJet settings.
2. Check gas pressure.
1.4540.037 – Watchdog Reset
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for operation.
u
Restart TecJet.
1.4540.038 – CAN Flow Demand Failed
Red alarm. Initiated by TecJet.
Cause
Corrective action
Position setpoint not received or
received too late.
1. Check TecJet setting.
2. Check cabling (→ Page 202).
1.4540.040 – TecJet Shutdown
Red alarm. Initiated by TecJet.
Cause
Corrective action
Summary alarm (for details, refer
to the source alarm).
u
Rectify cause of alarm.
MS150104/03E 2017-09
| Troubleshooting | 115
TIM-ID: 0000038611 - 005