1.4540.026 – Analog Input Low Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
TecJet setting is not correct.
u
Check TecJet setting.
1.4540.027 – Analog Input High Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
TecJet setting is not correct.
u
Check TecJet setting.
1.4540.028 – PWM Duty Cycle Low Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
TecJet setting is not correct.
u
Check TecJet setting.
1.4540.029 – Battery Volt Low Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Supply voltage has reached
minimum limit value.
1. Check supply voltage.
2. Check cabling (→ Page 202).
1.4540.030 – FGT Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Gas temperature before TecJet is
below the preset limit value.
1. Check TecJet settings.
2. Check gas temperature.
1.4540.031 – Delta P Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Pressure difference through
TecJet below the preset limit
value.
1. Check TecJet settings.
2. Check TecJet installation direction.
1.4540.032 – FGP Low Limit Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Gas pressure before TecJet is
below the preset limit value.
1. Check TecJet settings.
2. Check gas pressure.