113902 – SS Local Initiated Emerg. Stop
Red alarm. Initiated by EMU.
Cause
Corrective action
Emergency stop detected.
Emergency stop was released
manually (button), or ignition
system reported overspeed.
1. Clear emergency stop.
2. Check speed governor.
3. Check throttle closing position.
1.4510.186 – Error Status
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Summary alarm (for details, refer
to the source alarm).
1. Rectify cause of alarm.
2. Restart knock module.
1.4510.187 – Combined Error
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Summary alarm (for details, refer
to the source alarm).
u
Rectify cause of alarm.
1.4510.188 – Internal Error
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
Hardware not ready for operation.
1. Restart knock module.
2. Replace knock module.
1.4510.189 – Error Camshaft
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from camshaft sensor
for anti-knock control.
1. Check cabling (→ Page 202).
2. Check sensor B1.3, replace as necessary (→ Page 203).
1.4510.192 – Knock Sensor Error A1
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 202).
2. Check sensor (tightening torque, damage), replace as necessary