092 – SS No Starter Speed
Red alarm. Start is terminated.
Associated parameter 2.1090.923
Cause
Corrective action
Minimum speed for flushing
process and ignition release was
not attained.
u
Check starter system.
093 – SS T-Preheat
Red alarm. Engine shutdown.
Associated parameter 2.1090.922
Cause
Corrective action
Preheating temperature too low
(limit value 2). Coolant
temperature too low for engine
start.
1. Check preheating.
2. Check differential coolant pressure.
3. Check heating elements.
4. Check cabling (→ Page 202).
094 – LO T-Preheat
Yellow alarm.
Associated parameter 2.1090.921
Cause
Corrective action
Preheating temperature too low
(limit value 1). Coolant
temperature too low for engine
start.
1. Check preheating.
2. Check differential coolant pressure.
3. Check heating elements.
4. Check cabling (→ Page 202).
095 – AL Prelube Fault
Red alarm. Start is terminated.
Associated parameter 2.1090.920
Cause
Corrective action
Prelube fault.
1. Check oil pressure, oil temperature, oil level.
2. Check oil priming pump.
104 – AL Eng Hours Counter Defect
Yellow alarm.
Associated parameter 1.8004.623
Cause
Corrective action
Operating hours meter faulty.
Internal Engine Control Unit fault.
u
Replace Engine Control Unit.
MS150104/03E 2017-09
| Troubleshooting | 129