214 – SD P-Crankcase
Red alarm.
Associated parameter 1.8004.568
Cause
Corrective action
Crankcase pressure sensor faulty,
short circuit or wire break.
u
Check sensor and cabling (B50), replace as necessary
(→ Page 203) (→ Page 202). Error cleared after restarting the
engine.
216 – SD T-Lube Oil
Red alarm. Engine shutdown.
Associated parameter 1.8004.575
Cause
Corrective action
Engine oil temperature sensor
after oil heat exchanger faulty,
short circuit or wire break.
u
Check sensor and cabling (B7), replace as necessary (→ Page 203)
(→ Page 202). Error cleared after restarting the engine.
219 – SD T-Intake Air
Yellow alarm.
Associated parameter 1.8004.573
Cause
Corrective action
Intake air temperature sensor
faulty, short circuit or wire break.
u
Check sensor and cabling (B49.1 / B90), replace as necessary
(→ Page 203) (→ Page 202). Error cleared after restarting the
engine.
221 – SD P-Diff-Lube Oil
Red alarm.
Associated parameter 1.8004.585
Cause
Corrective action
Engine oil pressure sensors faulty,
short circuit or wire break.
u
Check sensor and cabling before filter (B5.3) and after filter (B5.1),
replace as necessary (→ Page 203) (→ Page 202). Error cleared
after restarting the engine.
227 – SD P-Lube Oil before Filter
Yellow alarm.
Associated parameter 1.8004.620
Cause
Corrective action
Engine oil pressure sensor before
filter faulty, short circuit or wire
break.
u
Check sensor and cabling (B5.3), replace as necessary
(→ Page 203) (→ Page 202). Error cleared after restarting the
engine.
134 | Troubleshooting | MS150104/03E 2017-09
TIM-ID: 0000038612 - 003