
153259 – HIHI Knock Integrator B9
Red alarm. Initiated by SAM.
Cause
Corrective action
Emergency stop due to knocking
detected in this cylinder.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check combustion chamber.
4. Check gas quality if feasible (methane number).
153260 – HIHI Knock Integrator B10
Red alarm. Initiated by SAM.
Cause
Corrective action
Emergency stop due to knocking
detected in this cylinder.
1. Check emission values.
2. Check ignition timing (→ Page 137).
3. Check combustion chamber.
4. Check gas quality if feasible (methane number).
153261 – HI Misfire Integrator A1
Yellow alarm. Initiated by SAM.
Cause
Corrective action
Misfiring was detected in this
cylinder.
1. Check emission values.
2. Check spark plug (energy level ignition system).
153262 – HI Misfire Integrator A2
Yellow alarm. Initiated by SAM.
Cause
Corrective action
Misfiring was detected in this
cylinder.
1. Check emission values.
2. Check spark plug (energy level ignition system).
153263 – HI Misfire Integrator A3
Yellow alarm. Initiated by SAM.
Cause
Corrective action
Misfiring was detected in this
cylinder.
1. Check emission values.
2. Check spark plug (energy level ignition system).
153264 – HI Misfire Integrator A4
Yellow alarm. Initiated by SAM.
Cause
Corrective action
Misfiring was detected in this
cylinder.
1. Check emission values.
2. Check spark plug (energy level ignition system).
MS150058/01E 2012-07 | Troubleshooting | 95
TIM-ID: 0000017543 - 001