472 – AL Stop SD
ZKP-Number:
Red alarm. Engine shutdown.
Associated parameter 2.8006.593
Cause
Corrective action
Engine stop, since all shutdown
channels detect “sensor defect".
u
Combined alarm (for details, refer to the source alarm).
473 – AL Wiring PWM_CM2
ZKP-Number:
Red alarm. Engine shutdown.
Associated parameter 1.8004.593
Cause
Corrective action
Cable break or short circuit on
channel PWM_CM2.
u
Check cabling to bypass throttle, replace bypass throttle if
necessary.
476 – AL Crash Rec.Init Fault
ZKP-Number:
Red alarm.
Associated parameter 1.8010.007
Cause
Corrective action
Crash recorder initialization
error.
u
Contact Service.
478 – AL Comb. Alarm Yel (Plant)
ZKP-Number:
Yellow alarm.
Associated parameter 2.8006.001
Cause
Corrective action
Combined alarm YELLOW from
plant.
u
Combined alarm (for details, refer to the source alarm).
479 – AL Comb. Alarm Red (Plant)
ZKP-Number:
Red alarm. Engine shutdown.
Associated parameter 2.8006.002
Cause
Corrective action
Combined alarm RED from
plant.
u
Combined alarm (for details, refer to the source alarm).
124 | Troubleshooting | MS150058/01E 2012-07