7.3.2 Crankcase breather (open-circuit crankcase ventilation) – Filter element
cleaning
Preconditions
☑ Engine is stopped and starting disabled.
WARNING
Compressed air
Risk of injury!
• Do not direct compressed-air jet at persons.
• Wear protective goggles / safety mask and ear protectors.
CAUTION
Excessive reaction time of cleaning agents on components.
Damage to component!
• Observe manufacturer's instructions.
• Wear protective clothing, gloves, and goggles / safety mask.
Clean filter element
1.
Remove filter element (→ Page 78).
2.
Clean filter element with cleaning agent.
3.
Remove cleaner.
4.
Blow out filter element thoroughly with compressed air.
5.
Install filter element (→ Page 78).
80 | Task Description | MS150049/02E 2012-11
TIM-ID: 0000003508 - 003