A-22
MS-9185 Server Board
Manual Rebuild
1. From the ACU Main menu, select
Manage Arrays
. From the List of Arrays,
select the array you want to Rebuild.
2. Press
Ctrl+R
to Rebuild.
Verifying Drives
If you are notified of a mismatch of data during a build of RAID 1, you have an option
of verifying your drives. To Verify the drives:
v
Note:
The Verify option is only available if the array is Optimal. If the array has
failed, you cannot rebuild the array.
1. Select the drives you want to verify.
2. Press
Ctrl+S
.
3. Verify will fix the errors found during the Verify operation and when it is
complete, you will be notified of the number of fixed errors.