Control Unit Models 9010 LCD and 9020 LCD
78
Appendix
MSA
GB
9010/20 LCD
Sensor data sheet DF-8401
Part No.: D0745720
Terminal Block
9010/9020
Sensor Type DF-8401
Caution:
Before connecting the measuring head, check hardware and software
settings.
Sensor type:
semiconcuctor/active/3-wire/4–20 mA/current source
Connection data:
Supply voltage:
16 – 32 V DC
Maximum current draw:
200 mA [switch-on current 400 mA, brief]
Power requirement:
5 W [excluding cable lengths]
Connection cable:
3-lead, 80 % shielded
Maximum resistance:
400 Ohm
Maximum cable length:
1.000 m [with 1.5 mm
2
lead cross-section]
Cable diameter:
8 – 12 mm
Permitted lead cross-section:
0.75 – 2.5 mm
2
Cable entry:
M20 X 1,5
Conditions for
use:
Assembly:
Wall-mounted
Protection:
IP 54 to EN 60529
Explosion protection:
None
Approvals:
None
Temperature:
–20 °C to +40 °C
Humidity:
5 – 90 % relative humidity; non-condensing
Pressure:
900 – 1,100 hPa
Weight:
approx. 1.1 kg
Dimensions W x D x H:
120 mm x 82 mm x 130 mm