General Information
Control Unit Models 9010 LCD and 9020 LCD
9
GB
3.2
Guide for using the manual
Reading and understanding this
Instruction manual
enables the proper management of the
Control Unit 9010/20 LCD.
The control units are normally furnished already predisposed in operation, configured and calibrat-
ed by MSA in relation to the sensor/transmitter that will be connected and in conformity with the
specific needs of the end User. In this case, it is recommended to take a look at the
Calibration
Data Sheet
attached to the Control Unit in order to verify the effective correspondence of the data
to the real needs.
In the event that the Control Units are not predisposed to satisfy the specific requirements of the
User, consult our technical support department or make the modifications to the Control Unit re-
lated to the defects discovered only after having read and understand the Instruction Manual. The
personnel that makes the modifications will have to be adequately prepared and aware of the
modifications that they will make.
The Technical Support Department of MSA is at the disposal of the customers in order to
supply information and clarifications.
3.3
General Description
The function of the Control Unit 9010/20 LCD designed and built with SMD parts for the purpose
of improving performance and reliability and managing many types of sensors and transmitters
that are suitable, in the most frequent applications, for monitoring the limits of flammability and
ambient toxicity of gases and vapours as well as for the measure of the oxygen in order to an-
nounce the possible deficiency.
In the planned cases, the Control Unit is configured in order to satisfy directive 94/9 EC,
better known as the ATEX directive. For different needs it is possible to configure it to
satisfy the particular specifications of the analysis systems.
The Control Units 9010/20 LCD enable the management, respectively, of one or two sensors/
transmitters [single or double channel].
Depending on the function of the applications, the sensors/transmitters can be connected via 2,
3 or 4 conductors.
Normally, beyond managing the input signal by current or voltage, the Control Units provide for
feeding every sensor/transmitter by current or voltage.
Display
back-lit LCD
4 digit; 7 segments
Pilot lights
High luminosity LED's
Warm-up and display time
60 sec./channel
Time-out function
2
6 min.
Default and configuration data
Memorised in EEPROM
Protections
AC/DC commutation because of absent mains voltage
Automatic electronics
Protections from accidental tampering
via Access Code and password
Watchdog and checksum electronic
diagnostics
A/D converter
For controls
16 bit ± 1 - 25 °C with
4 multiplexed inputs
For analogue signal
16 bit ±1 - 25 °C with
2 multiplexed signals
Dimensions of the front panel
3 U x 8 T. E
Weight
720 g
Electrical installation category
II
Summary of Contents for 9010 LCD
Page 1: ...Operating Manual CONTROL UNIT MODELS 9010 and 9020 LCD Order No 10093590 02 ...
Page 2: ...MSA AUER GmbH Thiemannstrasse 1 D 12059 Berlin Germany MSA AUER GmbH All rights reserved ...
Page 84: ...Control Unit Models 9010 LCD and 9020 LCD 84 Appendix MSA GB ...
Page 87: ......
Page 88: ......
Page 89: ......
Page 94: ......
Page 98: ......
Page 99: ......