2. Enter the new
password
twice.
3. Press the
Accept
button to save the modified password.
8.13.3 Creating, editing and deleting users
You can set the following options for all users:
▪ Username and password
▪ Role: You can assign a role to every user. The access rights to parame-
ters and events are linked to the roles.
▪ Group account: With this option, you can declare a user account to be a
group account (e.g. for access by different people). Users with a group ac-
count cannot change their own password. The password can only be
changed by the administrator.
▪ Active: You can activate or deactivate the user. Deactivated users cannot
log in. The user data is still stored in the device.
▪ Auto login: You can activate the Auto-login function for a user. This user is
automatically logged in when the system is restarted or another user logs
out.
Figure 95: Overview of users created
You can only create, edit, and delete users if you are assigned an adminis-
trator role.
When in delivery status, you can log in as the administrator as follows:
▪ User name:
admin
▪ Password:
admin
Creating users
To create a new user, proceed as follows:
1. Go to
Settings > Administration > User
.