SD34002g_e.doc / Sep-13
Page 36 / 60
F05
(continued)
Range
Default
F05.049 Switching Characteristics of Input „Cont.1“
0 … 7
0
0=
NPN (switch to – ), function active LOW
1=
NPN (switch to – ), function active HIGH
2=
NPN (switch to – ), rising edge
3=
NPN (switch to – ), falling edge
4=
PNP (switch to + ), function active LOW
5=
PNP (switch to + ), function active HIGH
6=
PNP (switch to + ), rising edge
7=
PNP (switch to + ), falling edge
F05.050 Function Assignment to Input „Cont.1“
0 … 17
0
0=
no function
1=
Substitute encoder frequency 1 by Set Value F03.030 (s)
2=
Substitute encoder frequency 2 by Set Value F04.042 (s)
3=
Substitute both encoder frequencies (1 and 2) (s)
4=
Freeze the actual frequency of encoder 1 (s)
a)
5=
Freeze the actual frequency of encoder 2 *) (s)
a)
6=
Freeze both encoder frequencies (1 and 2) *) (s)
a)
7=
Release maintain / latch state of output 1 / relay 1 (d)
8=
Release maintain / latch state of output 2 / relay 2 (d)
9=
Release maintain / latch state of output 3 / relay 3 (d)
10=
Release maintain / latch state of output 4 / relay 4 (d)
11=
Release maintain / latch state of all outputs / relays (d)
12=
Remote start-up delay, see F03.031 / F04.043 (s)
13=
Cycle display (d)
14=
Reset all min/max records to the actual display value (d)
15=
Hardware keypad lock (s)
16=
Read thumbwheel switches **) (d)
b)
17=
Start serial transmission (d)
F05.051 Switching Characteristics of Input „Cont.2“ (see „Cont.1“ F05.049)
0 … 7
0
F05.052 Function Assignment to Input „Cont.2“ (see „Cont.1“ F05.050)
0 … 17
0
F05.053 Switching Characteristics of Input „Cont.3“ (see „Cont.1“ F05.049)
0 … 7
0
F05.054 Function Assignment to Input „Cont.3“ (see „Cont.1“ F05.050)
0 … 17
0
F05.055 Switching Characteristics of Input „Cont.4“ (see „Cont.1“ F05.049)
0…3
0
This input will not support dynamic (edge-triggered) function!
F05.056 Function Assignment to Input „Cont.4“ (see „Cont.1“ F05.050)
0 … 17
0
Open (unconnected) NPN inputs are always HIGH (internal pull-up resistor)
Open (unconnected) PNP inputs are always LOW (internal pull-down resistor)
a) The latest actual measuring value is temporary frozen. This will affect the display and
the switching outputs as well. The measuring procedure however will continue in the
background.
b) Reading of the actual settings of the thumbwheels with models 642/644
(see chapter 8.3)
(s) = static function (on/off),
(d) = dynamic function, edge-triggered