SD34002g_e.doc / Sep-13
Page 40 / 60
6.2.9.
Serial Communication Parameters
F10
Range
Default
F10.106
Serial device address: Unit Number
0 … 99
11
You can assign any unit number between 11 and 99.
Addresses containing zeros are not permitted, since
reserved for collective addressing.
F10.107
Serial baud rate:
0 … 6
0
0=
9600 Bauds
1=
4800 Bauds
2=
2400 Bauds
3=
1200 Bauds
4=
600 Bauds
5=
19200 Bauds
6=
38400 Bauds
F10.108
Serial data format:
0 … 9
0
0=
7 Data, Parity even, 1 Stop
1=
7 Data, Parity even, 2 Stop
2=
7 Data, Parity odd, 1 Stop
3=
7 Data, Parity odd, 2 Stop
4=
7 Data, no Parity, 1 Stop
5=
7 Data, no Parity, 2 Stop
6=
8 Data, Parity even, 1 Stop
7=
8 Data, Parity odd, 1 Stop
8=
8 Data, no Parity, 1 Stop
9=
8 Data, no Parity, 2 Stop
F10.109
Serial Printer-Protocol: *)
0 … 1
1
0=
Output string = Unit Nr. – Data, LF, CR
1=
Output string = Data, LF, CR
F10.110
Serial Timer: for timed transmissions (sec.) *)
0.000 … 99.999
0.000
F10.111
Serial Parameter code: *)
0 … 26
14
Register code of the parameter to transmit
F10.112
Serial command "Set Frequency":
0 ... 3
0
Assignment of the input channels to be substituted by the
corresponding set frequency upon a serial “set” command
0 = Serial setting OFF
1 = Set encoder channel 1 to set frequency F03.030
2 = Set encoder channel 2 to set frequency F04.042
3 = Set both encoder channels to their set frequency
F10.113
Serial command "Freeze"
0 ... 3
0
Assignment of the input channels to be frozen upon a serial
“Freeze” command
0 = Serial Freeze command OFF
1 = Encoder 1 frequency enabled to freeze
2 = Encoder 2 frequency enabled to freeze
3 = Encoder 1 and encoder 2 frequency enabled to freeze
*) More details about serial operation are available in chapter 9.2