SD34002g_e.doc / Sep-13
Page 12 / 60
You can choose from the following operating modes:
Operating Mode
F02.004
Measuring Function of the unit
0
Single mode, evaluation of encoder 1 only
1
Dual mode, individual evaluation of encoder 1 and encoder 2
2
Sum mode, [speed of encoder1] + [speed of encoder2]
3
Differential mode, [speed of encoder1] - [speed of encoder2]
4
Multiplication mode, [speed of encoder1] x [speed of encoder2]
5
Ratio mode, [speed of encoder1] : [speed of encoder2]
6
Inverse ratio mode, [speed of encoder2] : [speed of encoder1]
7
Percentage mode, [encoder1 - encoder2] : [encoder2] x 100%
8
Inverse percentage mode, [encoder2 - encoder1] : [encoder1] x 100%
Your choice of operating mode will decide how in general the two encoder frequencies have to
be treated. It will not affect the scaling or the measuring characteristics or the final
presentation of the result.