The antenna connections for a three (3) Non–Duplexed 120 degree sector
configuration are shown in Table 5-19.
Table 5-20: Antenna Cables for Non–Duplexed 60 Degree Sector
Antenna # RX/TX
1A
RX1A (Main)
2A
RX2A (Main)
3A
RX3A (Main)
4A
RX4A (Main)
5A
RX5A (Main)
RX
6A
RX6A (Main)
1B
RX1B (Diversity)
2B
RX2B (Diversity)
3B
RX3B (Diversity)
4B
RX4B (Diversity)
5B
RX5B (Diversity)
6B
RX6B (Diversity)
1A
TX1A (Main)
2A
TX2A (Main)
3A
TX3A (Main)
4A
TX4A (Main)
5A
TX5A (Main)
TX
6A
TX6A (Main)
1B
TX1B
2B
TX2B
3B
TX3B
4B
TX4B
5B
TX5B
6B
TX6B
RF Main and RF Path
Cabling
This procedure is used to install the RF Cabinet Main RF path cabling.
The Main antenna connections are N–Female type.