ATP Tools and Materials
– continued
JAN 2002
1-15
SC
300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Communications Test Set
This procedure requires one of the following test sets:
Motorola CyberTest
Advantest R3465 and HP 437B or Gigatronics 8541C Power Meter
Hewlett–Packard HP 8935
Hewlett–Packard HP8921 (w/CDMA and PCS interface for 1.7/1.9
GHz) and HP 437B or Gigatronics Power Meter.
4–port 10 Base T ethernet hub (optional)
One 4–port, 10 base T, 10 Mbps, ethernet hub with BNC connector.
This is used for LMF to BTS ethernet connections. This is used to
connect the PCMCIA serial I/O port of the LMF to the RJ45 ethernet
cable.
GPIB cables
Two Hewlett Packard 10833A or equivalent; 1 or 2 meters long used to
interconnect test equipment and LMF terminal.
Power meter
This procedure requires one of the following power meters:
Gigatronics Model 8541C with 80601A power sensor capable of
measuring from –70 dBm to +23 dBm; supported by the LMF to
perform BTS Total Power measurement.
Hewlett–Packard Model HP437B with HP8481A power sensor
capable of measuring from –30 dBm to 20 dBm.
RF attenuators
30 dB, 10 Watt minimum RF attenuator to attenuate the transmitter
output for MicroCell tests.
BTS serial cable
One BTS serial cable to connect LMF to MMI/LMF connector.
Male N to male N cables
The following male N to male N cables are necessary to do this
procedure:
One male N to male N cable. The short RF test cable used for cable
calibration.
Two male N to male N cables. The transmit RF test cable and the
receive RF test cable used for ATP.
Male BNC to male N cable
One male BNC to male N cable. This cable is used to allow
self–calibration of the Communication Test Set.
1