7 - 20 RD5000 RFID Integrator Guide
To write to a locked tag
1.
Read the tag.
2.
Click on the tag, it appears in
EPC Mask
field. The tag is now selected for operations.
3.
Select the
EPC
memory bank as the target memory bank (since the EPC ID field is locked in this example).
4.
In the
Data
field write the new 96 bit EPC ID.
5.
Select
User Offset
as 2 (in words)
EPC
memory bank.
6.
Enter the access password (in the case of this example 22222222) in the field next to
Lock
.
7.
The following should be entered on the screen:
•
EPC
memory bank is selected.
•
EPC Mask
field, the tag to write to
•
Lock
, this has the Lock password
•
User Offset
field
•
Data field
, this is the new tag ID
8.
Click on
Write