Management Options
4-11
Figure 4.7 SNMP Access Control
2. Select the
Enable SNMP Access
checkbox to enable/disable the CB3000 SNMP interface
3. Enter a 4-32 character string for read-only SNMP permissions in the
Read Only
field. The default is
"
public
".
4. Enter a 4-32 character string for read/write SNMP permissions in the
Read Write
field. The default is
"
private
".
5. Enter Start IP and End IP addresses to specify a range of users that can access the CB3000 SNMP
interface. Use just the
Start IP Address
field to specify a single SNMP user. To leave access
unrestricted, do not enter an IP address.
For additional access control, an SNMP-capable client can be set up whereby only the administrator can
use a read/write community definition.
6. Click
Add
to add the specified IP address(es).
Once added, those IP addresses with an allowed designation display within the
Allowed IP Addresses
table.