background image

12A

12B

EN

EN

05. PROGRAMMING

MENU FUNCTIONS

01

 • Press the 

M

 key for 4 seconds to enter the programming menu. 

02

 • The display will show 

P1

 and press 

 

and 

▼ 

keys repeatedly until it shows 

P6

.

03

 • Press the 

M

 key once to access this submenu.

04

 • The display will show a value between 00 and 45, which identifies the thousands of 

maneuvers to which the motor will emit a warning maintenance light. 

Use the 

 

or 

▼ 

keys to put on the desired option.

05

 • Press the M key once to save this option. 

06

 • The control board will exit to standby mode (--) and the configuration is complete.

Funcionality

 • This notice serves to schedule revisions to the automatism, gate or 

springs after a certain number of complete maneuvers (open-stop-close-stop). When 

the automatismo completes the number of maneuvers defined by this menu, the LEDs 

will blink during 2 minutes after every maneuver, to emit the maintenance warning.

01

 • Press the 

M

 key for 4 seconds to enter the programming menu.

02

 • The display will show P1 and press 

 

and 

▼ 

keys repeatedly until it shows P7.

03

 • Press the M key once to access this submenu.

04

 • The display will show the value L0 or L1, which identifies the option in which the 

central is configured. Use the 

 

or 

▼ 

keys to put on the desired option.

05

 • Press the M key once to save this option. 

06

 • The control board will exit to standby mode (--) and the configuration is complete.

Funcionality

 • This menu allows you to enable or disable the possibility to program a 

new transmitter through one already configured (see page 11.A).

L0 means that this functionality is disabled, and 

L1

 means that is enabled.

• Programming maintenance warnings

• Programming transmitters using already configured 

transmitters

05. PROGRAMMING

MENU FUNCTIONS

01

 • Press the 

M

 button for 4 seconds to enter the programming menu. 

02

 • The display will show 

P1

 and press 

 

and 

▼ 

keys repeatedly until it shows 

P5

.

03

 • Press the 

M

 key once to access this submenu.

04

 • The display will show the value 

H0

 or 

H1

, which identifies the option in which the 

central is configured. Use the 

 

or 

▼ 

buttons to select the desired option.

05

 • Press the 

M

 key once to save this option. 

06

 • The control board will exit to standby mode (--) and the configuration is complete.

Functionality

 • This function causes the central to ignore all orders for the opening 

course sent by configured devices. 

• If you press the transmitter during the opening, the order is rejected and it continues 

to open 

• If you press with the door completely open, it will begin to close.

• If you press during closing, the gate reverses direction and starts to open.

When disabled, you can control the opening or closing of the gate whenever you want, 

and their behavior is open-stop-close-stop-open (...) by each time you press the 

transmitter.

• Enable/disable function condominium

Note •

 The 

P4

 and 

P5

 functions, when activated, prevent the gate to stay open. This 

way the gate will always open completely, starting the closure  after the pause time 

defined in 

P4

Note

 • The option 

00

 disables the maintenance warning. Any other option defines 

thousands of operations, the lowest value is 5000 operations (option 

05

) and the 

maximum is 45000 operations (option 

45

).

Whenever you want to reconfigure this option, you must perform two configurations. 

First, set the option to 

00

 to make a RESET to the counting maneuvers. After that, make 

a new one setting the new desired option.  The central will, from this moment on, start 

counting maneuvers to emit the maintenance warning.

01

 • Press the 

M

 key for 4 seconds to enter the programming menu. 

02

 • The display will show 

P1

 and press 

 

and 

▼ 

keys repeatedly until it shows 

P8

.

03

 • Press the 

M

 key once to access this submenu.

04

 • The display will show three numbers, each one for 2 seconds separated by 

intervals of 1 second between them.

After this the control board will automatically exit to standby mode (--).

Funcionality

 • This function serves only to show all completed maneuvers performed 

by the automatism (open-stop-close-stop). 

Example:

 If when entering the 

P8

 submenu the display first show nº

15

, then nº

65

 and 

finally nº

22

, means that a total of 

156522

 complete maneuvers have already been 

done.

RESET

 through the menu 

P6

: To restart maneuver counting, go to 

P6

 submenu, and 

• Counting maneuvers

Summary of Contents for ROSSO EVO

Page 1: ...v4 0 REV 05 2018 EN USER S AND INSTALLER S MANUAL ROSSO EVO...

Page 2: ...ubstances in electrical and electronic equipment Applicable in countries with recycling systems This marking on the product or literature indicates that the product and electronic accessories eg Charg...

Page 3: ...uct or other use than that for which it was designed The ELECTROCELOS S A is not responsible if safety standards were not taken into account when installing the equipment or for any deformation that m...

Page 4: ...1200N Operating temperature 25 C a 70 C 25 C a 70 C 25 C a 70 C Thermal protection 120 C 120 C 120 C Protection grade IP20 IP20 IP20 Working frequence 70 70 70 Courtesy Light 3 minutes 3 minutes 3 min...

Page 5: ...the side holes and create a leverage effect to release the indents fittings between the top cover and the body Then just remove the cover by lifting it To replace the cover you must first fit the bac...

Page 6: ...no technical defects such as friction points prison that may jeopardize the automatism durability Make sure the door is in good condition to install the motor To do so raise it manually to 800mm 1600m...

Page 7: ...Attach the rail s support plate to the lintel as visible in the image 15 In the image 16 if can be seen the distance to keep between the gate rail and support plate s upper part 125 175mm Note If you...

Page 8: ...st be centered horizontally with the panel so that it stays aligned with the rail It should also be to fixed as higher as possible picture 24 07 Now attach the two connecting rods between the trolley...

Page 9: ...02 Steel rail 03 Rail to ceilling s struture s fixation plate 04 Bracket for structure fixing 05 Fast rail to ceilling s struture s fixation plate 06 Trolley with unlocking system 07 Rail to lintel s...

Page 10: ...amming the Follow Me function Enable disable condominium function Programming opening and closing courses Programming maintenance warnings Programming the automatism force level Programming transmitte...

Page 11: ...tomatically to the programmed limits showing the message OP during the opening and CL during the closing When it finishes closing the control board will exit to the stand by mode Programming opening a...

Page 12: ...is configured Use the or buttons to select the desired option 05 Press the M key once to save this option 06 The control board will exit to standby mode and the configuration is complete Functionality...

Page 13: ...can be enabled or disabled via the P7 menu see pag 10 A Delete all configured transmitters 01 In stand by mode press the T key for 10sec until the display shows dl The control board has a maximum cap...

Page 14: ...and rail motion axes The pinions at both ends of the rails as well as their supporting bearings and chain should be lubricated at least once every year 06 POST INSTALLATION STOPPER AT THE OPENING The...

Page 15: ...irection In case of automatism failure or malfunction you must detect the fail component motor or central To do that you should test the motor directly connected to a 24V DC power source in order to u...

Page 16: ...l an external receiver MR5SP EXCESSIVE WORKING TIME The motor stops functioning During programming does not record the course The engine is more than 1 minute in continuous operation The motor does no...

Page 17: ...m is the fuse electrical cables or electrical current itself Check all systems 1 Give a start on the transmitter to open and check the LEDs behavior 2 If it blinks twice then the connection with the p...

Page 18: ...TROL BOARD Pushbutton Key Selector or 230V Power Supply Fuse 2 5AL 250V Transformer IN 230V OUT 24V MOTOR m x 240W CONTROL BOARD DISPLAY BOARD Battery 24V CON1 1 Pedestrian door 2 PB 3 PE 4 GND 5 24V...