while the display shows any of the options in this submenu, press the
▲
and
▼
keys
simultaneously for 10 seconds. The control board will automatically exit to standby
mode and the
RESET
to the
P8
menu is complete.
05. PROGRAMMING
PROGRAMMING TRANSMITTERS
• Standard configuration using the T key on the display
01
• In stand-by mode (--) press the T key until the display shows SU.
02
• Press two times the transmitter’s desired key to configure until the engine starts
moving.
Note
• Repeat these steps whenever you want to configure new transmitters.
• Configuration through already configured transmitters
Since there is already configured transmitter, you can use it to open the control board’s
memory by distance in order to configure new transmitters.
This allows easy configuration without requiring direct access to the engine.
01
• In Stand-By mode (--) press
3
and
4
keys from an already configured transmitter
until the courtesy LEDs start to blink. Now release the pressed buttons.
02
• Press the new transmitter’s desired key to configure until the automatism starts
moving.
Note .1
• Repeat these steps whenever you want to configure new transmitters.
Note .2
• This feature can be enabled or disabled via the P7 menu (see pag 10.A).
• Delete all configured transmitters
01
• In stand-by mode (--) press the T key for 10sec until the display shows dl.
The control board has a maximum capacity of 30 transmitters and only
accepts Motorline Rolling Code transmitters!
05. PROGRAMMING
MENU FUNCTIONS
01
• Press the
M
key for 4 seconds to enter the programming menu.
02
• The display will show
P1
and press
▲
and
▼
keys repeatedly until it shows
P9
.
03
• Press the
M
key once to access this submenu.
04
• The display will show the value
E0
or
E1
, which identifies the option in which the
central is configured. Use the
▲
or
▼
keys to put on the desired option.
05
• Press the
M
key once to save this option.
06
• The control board will exit to standby mode (--) and the configuration is complete.
Funcionality
• The option
E0
disables the use of this functionality while the
E1
option
activates it.
When the function is activated, the gate only opens/closes if the service door is closed
or if the side sectional door's photocells are not interrupted.
With the service door openned, the control board rejects any opening or closing order.
If the service door opens during any gate maneuver, the gate stops immediately.
If the photocells are interrupted during a closing maneuver, the automatism will stop
immediatly, but if it is during an opening maneuver it will stop and invert (close) for 1
second.
• Service door / Photocells for side door open