TriStar MPPT-600V-TR Operator's Manual
Ethernet Cross-over
Cable
Figure 5-3. Ethernet network diagrams.
Factory Default Network Settings
DHCP
enabled
Live View Web Address
http:// serial number **
IP
192.168.1.253 (if DHCP is not enabled)
Subnet
Mask
255.255.255.0
Gateway
192.168.1.1
Primary DNS Server
169.254.1.1
MODBUS TCP/IP
TM
Port
502
** The Live View web address is unique to each controller. If the TS-MPPT-600V-TR serial number is 09501234, then the Live
View address is: http://tsmppt09501234. The Live View address is printed on the serial label on the side of the unit for reference.
The controller’s MAC Address is located on the serial label on the side of the controller.
Two (2) LEDs on the Ethernet jack indicate link and activity status.
Condition
Yellow LED
Green LED
Network Connection OK
ON
OFF
Network Activity
ON
Blinking
Error
OFF
ON
Web Pages
Connect the TS-MPPT-600V-TR controller to the network using an Ethernet cable. Wait 5 to
10 minutes for the controller to connect to the network. Open a web browser on any PC on
the network. Enter the Live View web address in the address bar of the web browser. The
TS-MPPT-600V-TR main Live View webpage will load. Links are provided to real-time data,
history, and network settings adjustment pages.