32
Installation
Replace the wiring divider, and secure with the screw, as shown in Steps 1-2 in Figure 3-12
above. Carefully re-position the GFPD power wires as shown in Step 2. Replace the box
covers, and secure each with four (4) screws, as shown in Step 4 above.
Step 7 - Remote Temperature Sensor
The included Remote Temperature Sensor (RTS) is recommended for effective temperature com-
pensated charging. Connect the RTS to the 2-position terminal located between the pushbut-
ton and the LEDs (see figure 2-1). The RTS is supplied with 33 ft (10 m) of 22 AWG (0.34 mm
2
)
cable. There is no polarity, so either wire (+ or -) can be connected to either screw terminal. The
RTS cable may be pulled through conduit along with the power wires. Tighten the connector
screws to 5 in-lb (0.56 Nm) of torque. Separate installation instructions are provided inside the
RTS bag.
Figure 3-12. Replacing Wiring Divider and Covers
2
3
1
4
Replace Cover
Secure Wiring
Divider with screw