22
1
Replacing Blade Sets (continued)
11
Slide the blade adjustment assemblies
and the blade adjustment cams onto the
dowels of the new blade set
12
Slide the new blade set into the slots of
the creasing unit as shown
NOTE:
The blade can be fitted with the ANVIL at
the bottom or with the ANVIL at the top. The
blade set is supplied from the factory with
the ANVIL at the bottom. The blade can be
changed to have the ANVIL at the top, which
may improve the repeatability of the fold
relative to the crease for certain fold types or
when using lighter stocks.
NOTE:
For optional blade sets see “Optional Parts” in this section.
13
Rotate the blade adjustment cams until they are just tight, and then back off slightly.
Switche the machine on, reset blade to “Top Dead Centre” and make final adjustments.
14
Refit the Sheet Guide Assembly
15
Close the top cover
16
Test the crease for form